2002 National Electrical Code® Search Term Index by David U. Larson  ElectricianEducation.com

Click HERE for ElectricianEducation homepage.

abandoned  372.13
abandoned audio distribution cable  640.2
abandoned fire alarm cable  760.2
abrasives foreign material  110.12C
AC resistance for aluminum wire  Chapter 9 Table 9
AC resistance for uncoated copper wire  Chapter 9 Table 9
access to occupants  225.35  240.24
additional grounding requirements table  250.3
adequate, not necessarily  90.1B
adjacent conductors  310/10 FPN (4)
adjacent devices  404.8B
adjacent runs of heating cable  424.41B
adjustable speed drive control example calculation Appendix D10
adjustable speed drive systems  430.2
adjustable-trip circuit breaker  240.6B
adobe  334.10B3
aerial cable identification  200.6A(4)
AFCI arc fault circuit interrupter  210.12  440.65
aggregate  314.29ex.
air blowers  680.62A(1)
air conditioner branch circuits  440.6  440.31  440.32
aircraft batteries  513.10
aircraft hangers  500.9
airflow  424.59
airflow can be reversed  110.57
airport runways  300.50A ex. 5
airspace  312.2Aex., 312.11, 410.34
airspace 1/4 inch  300.6C
airstream duct heater  424.57
air terminals  250.60
alcohol based windshield washer fluid  511.3
alley clearance service 18 feet 230.24
ALR aluminum letter designation  404.14C
alternate power source  517.2
alternating current resistance 600v 3Ø Chapter 9 Table 9
aluminum alloy  810.11
aluminum dust  500.6B(1) FPN
aluminum electrode conductor not closer than 18 inches to earth 250.52B
aluminum letter designation ALR  404.14C
amateur radio stations  810.51
ambient temperature  310.10 FPN (1)
ambulatory health care facility  517.2
American Wire Gage AWG 110.16
ampacities of conductors free air table  310.17
ampacities of conductors table  310.16
ampacity adjustment factor table  310.15B(2)a
ampacity adjustment for cords and cables table  400.5
ampacity calculation  Annex B (back of the book)
ampacity correction for fill table  310.15B(2)a
amplifier audio  640.2
amusement rides  525.5B
anesthetizing location  517.2
angle pull six times  314.28A(2)
angular substances  300.5F
animal hides  300.6C FPN
antenna clearances specifications  810.18A
appliance load fixed four or more 75% 220.17
appliance outlets within 6 feet of intended location 210.50C
application provisions  310.13
application provisions for fixture wire table  402.3
appurtenance, architectural  110.26F(2)
arc carbon  540.2
arc fault circuit interrupter  440.65
architectural appurtenance  110.26F (2)
arcing effects  110.3A(6)
arcing parts  240.41
area compact aluminum conductor  Chapter 9 Table 5A
armature shunt  430.29
array  690.2
askarel insulated transformers  450.25
asphalt  426.20C1
associated apparatus  504.2
associated nonincendive field wiring  500.2
associated wiring systems bonding 250.60 FPN2
assured equipment grounding 527.6B2
athletic training rooms  680.60
attached garage needs receptacle outlet  210.52G
attached main bonding jumper  250.28C
attachment cap configuration drawing  552.44C
attic  600.21E
attic light 210.70A3
audience area of theater  520.1
audio amplifier  640.2
audio autotransformer  640.2
audio distribution cable abandoned  640.2
audio signal processing equipment  640.2
audio system  640.2
audio transformer  640.2
authorized management personnel  240.24B
automatic transfer switches  701.7C
autotransformer  410.78
autotransformer circuit  210.9,  215.11
autotransformer drawing  450.4
AWG American Wire Gauge  110.16
back-fed overcurrent devices  408.16F
backfeed  490.44B
backfeed source of power  404.6C ex.
backfill 300.5F
balancer sets  445.12D
balconies  110.33B
balconies clearance table  225.61
balcony, location of live parts  110.27A(3)
baled waste kapok  500.5D(1)
ballroom demand factor 100% table 220.11
barbed wire  110.31
bare conductors Chapter 9 Table 8 Note 8
bare metal parts spacing table  408.36  430.97
barriered, energized parts of switches  404.5
bar type counter  210.52A(3)
baseboard heaters  424.9 FPN
bathroom GFCI receptacle within 3 feet adjacent wall 210.52D
bathtub  406.8C  410.4D
bathtub clearance to fixtures 3ft horizontal  410.4D
bathtub clearance to fixtures 8ft vertical  410.4D
bathtub rim 410.4D
battery, aircraft changed outside  513.10
battery circuits  690.85
beans  500.5C1 FPN
beating rain  406.8A
bender table full shoe  344.24
bending space  312.6A
bent parts  110.12C
binding screw conductor #10 or smaller  110.14A   334.40B
bipolar photovoltaic array  690.2
birds  502.9
blades  406.6
block  800.2
blocking diode  690.2
blue  322.120C  400.22C  424.35  504.80C
blue, light as grounded conductor  400.22C  504.80C
blue non heating lead 208 volts  424.35
boat houses receptacles must be GFCI  210.8A(8)
boat yard branch circuits  555.19
body of water  680.1
bolts to fasten enclosure  314.23D(1)
bonding jumper 12 1/2%  minimum  250.28D
bonding jumper can be wire, bus, screw  250.102A
bonding limits potential differences  250.60 FPN
bonding type locknuts  250.92B(4)
border light  520.2
bored holes 1 1/4 inch from edge  300.4A(1)
bosses  300.4F ex.
bottom shield  324.2
box minimum depth 1/2 inch  314.24
box over 100 cubic inches  314.40C
braces as support for mast  230.28
braid colored  400.22A  400.23A
brake coils  610.42B(3)
branch circuit over 50 amperes supply non-lighting 210.23D
branch circuits requirements table 210.24
brass  314.40B
brazing splices  110.14B
breakout assembly  520.2
brick wall grounded  110.26A(1)
bridge expansion joints  426.21C
brittle  356.10 FPN  378.10 FPN
broadband cables  830.58E
broken parts  110.12C
bronze  810.11
bronze box  314.40B
bronze cast  250.70
brown  424.35  517.160A5(2)
brown non heating lead 277 volts  424.35
building clearance table  225.61
building component  545.3
building system  545.3
bulk storage plant  515.2
bull switch  530.2
bundled  520.2
bundled cables exceed 20  310.15B(2) ex.5
buried pipe  250.188E
bus enclosure table  408.10
bus main bonding jumper  250.28A
busway taps  240.20E
butt  404.6C
cable connector FCC  324.2
cable installation dimensions drawing  310.60
cable seals  505.16A(2)
cable tray system  392.2
cables in tunnels over 600 volts  110.51C
cadmium  300.6A
calculations example problems Appendix D (back of the book)
camping trailer  551.2
candelabra-base pendant conductors 18AWG or larger 410.27B
canned pumps  501.5F(3)
canneries  300.6C
canopy switches specifications  410.38C
capacitive reactance Chapter 9 Table 9
carbon arc  540.2
carbon black  500.6B2
carbon disulfide  500.6A FPN3
carbonization 503.1
carnival  90.2A2  640.3G
carpet  725.61C  800.50
carpet squares  324.2
cars in tunnels over 600 volts covered 110.51A
cartridge fuses  424.22C FPN
casings  250.112M  300.6C FPN 
casings (animal)  300.6C FPN
cast bronze  250.70
cathodic protection systems 250.6E
CATV community antenna television  820.1
catwalks clearance  225.61
caustic alkalis  330.12
ceiling fan  422.18
ceiling fan outlet  314.27D
ceiling grid  300.11A
ceiling support wires  300.11A(1)
cell  372.2  374.2
cells  480.6
cellulose nitrate film storage vault  530.51
cement  334.10B(3)
center pivot irrigation machines  675.2
central heating branch circuit  422.12
central vacuum  422.15
chair lift runway  620.34
charcoal  500.6HB2
charge controller  690.2
chemical action, deteriorated by not permitted  110.12C
chemical deicers  300.6C FPN
chemicals  300.6C FPN
chimney  450.24
chimneys clearance 3 feet  225.19B
chips  372.9
chlorine  330.12
cigarette lighter  551.10H
cinder fill  330.12  342.10C
cinders  300.5F
circuit breakers in parallel  240.8
circuit directory  408.4
circuits 480 volts  210.6D
circuits over 600 volts  210.6E
circuits 277 volt  210.6C
circular mils of conductors  Chapter 9 Table 8
circulation system  680.61D(1)b
circuses  640.3G
class gray 200.10D FPN
Class I, Class II Division 2 locations drawing  516.3B(2)
Class I Division 1  500.5B(1)
Class I Division 3  500.5B(2)
Class I locations gases or vapors  500.5B
Class I locations table  514.3B(1)
Class II Division 1  500.5C(1)
Class II Division 2  500.5C(2)
Class II locations  500.5C
Class II temperatures table  500.8C(2)
Class III Division 1  500.5D(1)
Class III Division 2  500.5D(2)    
Class III locations  500.5D
class 2 and class 3 circuit drawings  725.41
clean surfaces  250.12
cleaner foreign materials  110.12C
cleaning lighting fixtures  410.4C (3)
clearance above roofs  230.24A
clearance over bathtub 3ft horizontal  410.4D
clearance over bathtub 8ft vertical 410.4D
clearance over buildings  225.61
clearance over roadways  225.60
climbing space around communications wiring  225.14D
clips 410.16C
clips to fasten enclosure  314.23D(1)
clock operated switch  680.23F(2)b
closed construction  545.3
closed loop  300.15M
closed loop power distribution  240.20C
closet storage clearance diagram  410.8
closet storage space  410.8A
closet storage space drawing  410.8
clothes dryer demand factors  table  220.18
clothes dryer dwelling 5000 or nameplate  220.18
clothes dryer existing grounded  250.142B ex.1
clothes hanging rod  410.8A
clothing  500.5D1  FPN 1
clothing manufacturing  500.5D(1)
coal  500.6B2
coal leads  427.18A
CO/ALR copper/aluminum  404.14C
coated conductor resistance Chapter 9 Table 8
coaxial cable  620.36
cocoa  500.5C1  500.8A FPN
cocoa fiber  500.5D(1) FPN2
coefficient of expansion  300.7B FPN
coke dust  500.6B2
collector rings  490.54  675.2
collectors  610.22
colored braid  400.22A  400.23A
colored separator  400.22D
colored stripe  200.6D
column width panelboard  300.3B(4)
combined rating of disconnects  230.80
combustible gas detection system  500.2  505.2
combustible metal ducts Class II 500.5C
commercial premises neutral 20 percent  250.184D(1)ex.
common area branch circuits  210.25
common area house load  220.32B
common bonding grid  680.26C
common coupling point  692.2
common neutral ampacity  225.7B
common neutral feeder  215.4A
common neutral outdoor lighting  225.7B
common return  610.15
common return pipe organ minimum  #14  650.5A
communicating fire  408.7
compact aluminum conductor dimensions  Chapter 9 Table 5A
compact stranding   table C3A Note Appendix C
compact stranding 9% smaller  Chapter 9 Table 8 Note 3
compartments  386.70
complete system free from shorts 110.7
compressed stranding 3% smaller Chapter 9 Table 8 Note 3
compression glands  680.52B(1)a
compressors in tunnels over 600 volts covered 110.51A
concentric knockouts (same center point)  250.92B  250.97
concentric stranded conductors  table C3 Note Appendix C
concrete-encased  250.52A(3)
concrete wall grounded  110.26A(1)
condition 1  exposed live parts one nothing other  110.26A(1)
condition 2  exposed live parts one side grounded other  110.26A(1)
condition 3  exposed live parts both sides  110.26A(1)
conductivity 100% copper 61% aluminum Chapter 9 Table 8 Note 4
conductor application table  310.13
conductor dimensions Chapter 9 Table 5
conductor minimum size table  310.5
conductor properties Chapter 9 Table 8
conductor support spacing table  300.19A
conductor volume allowance table  314.16A
conductors in tunnels over 600 volts  110.53
conductors on poles  225.14D
conductors racked in surface enclosures  110.12B
conductors normally copper  110.5
conduit body fill requirement  314.16C(2)
conduit area Chapter 9 Table 4
conduit bushing temperature 300.4F
conduit fill Appendix C (back of the book)
conduit fill EMT Article 358 Chapter 9 Table 4
conduit fill ENT Article 362 Chapter 9 Table 4
conduit fill FMT Article 348 Chapter 9 Table 4
conduit fill IMC Article 342 Chapter 9 Table 4
conduit fill LFNC-B Article 356 Chapter 9 Table 4
conduit fill LFNC-A Article 356 Chapter 9 Table 4
conduit fill LFMC Article 350 Chapter 9 Table 4
conduit fill RMC Article 344 Chapter 9 Table 4
conduit fill RNC 80 Article 352 Chapter 9 Table 4
conduit fill RNC 40 Article 352 Chapter 9 Table 4
conduit fill percent table Chapter 9 Table 1
conduit fill table shart  Annex C
conduit nipple 24 inches or less 60% fill Chapter 9 Table 1 Note 4
conduit seals  505.16A(1)
conduit support weight (single) 20 pounds  314.23F ex. 2e
configuration drawing attachment cap  552.44C
confusion  90.7
connector strip  520.2
conspicuous warning signs  110.27C
contiguous  390.3D
continuity  250.53D(1)
continuous building management  240.24B
continuous load overcurrent device  210.20A
control drawing  500.2
control system elevator  620.2
control system elevator drawing  620.2
convenient, not necessarily  90.1B
covering of cable notes to table  400.4
converter  551.2
conveyors in tunnels over 600 volts covered 110.51A
convolutions  348.28
cooking hood  410.4C4
cooking hood lighting fixture  410.4C(1)(4)
coordinated short-circuit protection  240.12
coordination definition  240.2
copper clad steel  810.11
cord and plug connected appliance 80%  210.23A(1)
cord and plug connected lighting 50%  210.23A(2)
cord pendants  210.50A
corner-grounded delta  240.85
corner-grounded delta transformer  250.20FPN
corrosion, deteriorated by  110.12C
corrugated metallic sheath  330.2
cotton  500.5D1 FPN 1
counter-mounted cooking unit  210.19A3
counter mounted cooking units existing grounded  250.142B ex.1
counter tops need GFCI receptacles  210.52C
counterweight  620.21A(4)
cove lighting space adequate to maintain  410.9
cover definition  300.50 Note
cover (industrial surface) mounted receptacle  406.4C
cover requirements table  300.5
cover  table  300.5 note 1
cranes branch circuit  610.42
crawl space  210.8A(4)
critical branch  517.2
crossings FCC  324.18
crowfeet  410.16D
cubic inch requirement per conductor table  314.16B
cultivated  225.18(4)  230.24B  830.11D(3)
cultivated land clearance service 18 feet 230.24
current limiting device  240.2
current transformer  240.20A  240.100A1  110.23
current transformer shorted  110.23
curtain machines  520.48
d flameproof protection type  505.8A
dairy processing  300.6C
damaged parts - broken, bent, cut, deteriorated  110.12C
damp location conductors  310.8B
damp paper  300.6C
datum plane  555.2  555.19
dead end  390.10
dead ends wireways  376.58  378.58  390.10
dead-front  408.18
dead-front assemblies  110.26A1a
dead front switchboards  250.174B
dedicated equipment space  110.26E
deflected  376.23A
deflected conductors  376.23A
deflecting cables  300.19B(3)
dehydration 503.1
deicers  300.6C FPN
deicing branch circuits  426.4
deicing equipment receptacle  210.8A(3)
delta breakers  408.16E
delta-connected  250.188A  250.20B3  250.20.4FPN
delta-connected secondary  215.8
delta-delta transformers  240.4F
delta transformer corner grounded  250.20FPN
derating factors  310.15B(2)a
derived neutral  250.182
derived phase conductors  250.30A1 ex.2
designated polarity not to be removed  200.11
design specifications not intended  90.1C
detached garage no receptacle if no power  210.52G
deteriorating effect  110.11
deuce board  530.2
device yoke  250.146A  250.146B
diagram of feeders  215.5
diameter compact aluminum conductor  Chapter 9 Table 5A
diameter of conductor  Chapter 9 Table 8
diathermy equipment  517.2
die-cast  314.40B
dielectric heating  665.2
dielectric strength test 1 minute 900 volts  550.17A
different intrinsically safe circuits  504.2
diffraction equipment  660.23B
diffusers  410.4C2
dikes  450.27
dimmer switches  404.14E
diode blocking  690.2
dip tank drawing  516.3B(5)
dip tanks  516.3B5
direct current resistance  Chapter 9 Table 8
directional boring  300.5K
directory required  225.37 ex. 1
dirt  314.27C ex.
disconnects six maximum  225.33
dish antenna systems  810.1
dishwashers  422.16B2
dishwasher cord maximum length 4 feet  422.16B2(2)
dispensers classified locations  514.3
dissimilar metals  342.14  344.14 
dissimilar metals, connections not intermixed  110.14
distinguishably different 200.6D
distribution apparatus  250.110 ex.2
distribution centers  90.8A
distribution panelboard  550.2
distribution point  550.2
diversion charge controller  690.2
diving platform clearance table  680.8
diving tower clearance table  680.8
docks  513.7E
documented safe switching  225.30E
domed covers fill calculation   314.16A
doors opening 90 degrees  110.32
double ended services  250.24A(3)
double insulated  250.114
double insulated pool pump  680.21B
double lock nuts  250.97ex.b
double pole switched lampholders  410.48
draglines covered 110.51A
drain arranged for raceways on exterior  225.22
drain for raceways  230.53
drain holes  600.9D
drain plugs  368.26
dredges covered  110.51A
dressing rooms  530.31
dried hay  500.8A  FPN
drills in tunnels over 600 volts covered 110.51A
drip loop  230.24B  230.54F
drip proof enclosures tunnels  110.59
driveways clearance service 18 feet  230.24
drop box  520.2
dropped ceilings  400.8 (5) 424.41A
drums  250.136B
dry board installation heating cable  424.41G
dry location conductors  310.8B
dry location 90 degrees centigrade table  310.13
dry partitions  380.3
drywall  314.21
dual fed services  250.24A(9)
ducting metal  250.2FPN
duct bank drawings  310.60
duct heaters  424.67
ducts for dust  300.22A
dumbwaiters  620.1  620.5A
dumbwaiters branch circuit  620.61
dust ignition proof  500.2
dusttight  500.2
duty cycle service table  430.22E
dwelling unit optional calculation  220.30
e protection type  505.8A
earth itself  250.2 FPN
eccentric knockouts (same edge point)  250.92B  250.97
edge of the roof service clearance  230.24
Edison base fuse 30 or less  240.51A
Edison base lampholder  422.40
effective grounded metal faceplates in receptacles in RV's  551.47M
effective ground-fault current path  250.2
effective grounding path  250.68B
effective Z definition Chapter 9 Table 9 Note 2
effective Z for aluminum wires  Chapter 9 Table 9
effective Z for uncoated copper wire  Chapter 9 Table 9
efficient, not necessarily  90.1B
egg  500.5C(1)FPN
egress  110.26C2  410.73E4
ejector mechanisms  406.6C
elbow metal  250.86 ex.3
electric shock protection  90.1D FPN
electric vehicle  625.2
electric vehicle inlet  625.2
electric vehicle nonvented storage battery  625.2
electrical area classifications table  515.3
electrical datum plane  555.2
electrical duct drawing  310.60
electrical ducts  310.60A
electrical equipment  500.2
electrical life support equipment  517.2
electrical noise  250.96B  406.2D
electrical ranges calculations  210.19A(3)
electrically connected  200.3
electric signs branch circuits  600.6
electric utility, not covered  90.2B5
electric vehicle cable type EV table  400.4
electrocution  422.41
electrode spacing greater than 6 feet  250.56FPN
electrode type boiler grounded  250.142B ex.1
electroendosmosis  310.13 FPN
electrolysis of the sheath  110.36
electrolytic cell line working zone  668.2
electrolytic cells feeders  668.3C1  215.1
electromagnetic induction is not electrically connected  200.3
electromagnetic interference  250.96B  406.2D
electronic actuated fuses table 450.3A Note 4
electronic equipment  500.2
electronic equipment voltage drop 1.5 2.5 overall  647.4D
electrostatic  422.12 ex. 516.10A(2)  516.10B  516.10C
elevator branch circuit  620.61
elevator cable type E table  400.4
elevator single line diagram drawing  620.13
elevator trailing cable table  400.4 note 5
elliptical cross section cable Chapter 9 table 8 Note 9
embedded cables  424.40  424.41D
embedment  314.23G
emergency system  517.2
emerging from grade to 8 feet  300.5D(1)
EMT minimum 1/2 maximum 4 inch  358.20
enamel  250.12  250.96A  300.6A
encapsulated in  680.23B(4) 680.26B(1)
encapsulation "m"  505.2
end-cap  322.40
end to end connection of fixtures  410.32
engineered cabling system  300.50C ex.
engineering supervision ampacity calculation Annex B
ENT minimum 1/2 inch maximum 2 inch  362.20
envelope ferromagnetic  426.2 
environmental air  830.55B
equipment grounding conductors table  250.122
equipment rack  640.2
equipment system  517.2
equipotential plane  550.2
escalators  620.5A
escalators branch circuits  620.61
escutcheon  240.83B
essential electrical system  517.2
evenly proportioned load  210.11B
example problems/calculations Appendix D (back of the book)
excelsior  500.5D(1) FPN2
excitation conductors over 600 volts  300.3C(2)a
existing dwelling additional loads  220.31
exothermic welding  250.64C  250.8  680.26C
expansion fittings  250.98  352.44
expansion joints for heat panels  424.98B
explanatory material  FPN  90.5C
explosion proof apparatus  500.2
exposed conducting surfaces  517.2
exposed live parts both sides condition 3  110.26A(1)
exposed live parts one nothing other condition 1  110.26A(1)
exposed live parts one side grounded other  110.26A(1)
exposed terminals  406.4F
extra working space  110.26C(2)b
faceplates  404.9
face-up position  406.4E
factory elbow  342.6
factory-wired  430.7D
fairs  640.3G
fan circuit interlock  424.63
fan interlock circuit  424.63
farm load  220.40
farm load demand factors table  220.40
farm loads service size method  220.40
farm load total table  220.41
fat  500.5B(1) FPN5
fault closing rating  225.53
fault-closing rating disconnect  230.205B
fault current protection  90.1D FPN
fault tolerant external control conductors  695.2
FCC system  324.2
feeder assembly  550.2
feeder for generator example calculation Appendix D9
feeder neutral  220.22
feeder taps  240.20
feed-through conductors  312.11D
fence fabric  110.31
fences  250.190
ferromagnetic  300.20A ex2
ferromagnetic envelope  426.2
ferrous metal  404.9C
ferrous (steel)  344.2
fertilizer  300.6C FPN
festoon  410.27  520.65
fiber board surface mounted fixture  410.76B
fibers and flyings Class III 500.5D
field assembled breaker in parallel no 240.8
film storage vault  530.51
filter drains  368.26
final spans  225.19D
final span overhead conductors  225.19D
fine print note FPN  90.5C
fire alarm cable abandoned  760.2
fire alarm circuit  760.2
fire alarm circuit integrity cable  760.2
fire barriers  368.25
firedamp  505.6
fire dampers transformer vault  450.45C
fire escape  314.23H 2
fire escapes clearance for service  230.9A
fire ladders  225.19E
fire ladder zone to raise ladders  225.19E
fire rating 3 hours  110.31A
fire stopped  300.21
fire wall  368.25
first make equipment grounding  250.124
fish  547.1A
five threads fully engaged  505.9E
fixed appliance  550.2
fixed appliance 75% 4 or more 220.17
fixed ladders  314.59
fixed panels need receptacles  210.52A(2)
fixed trip circuit breakers  240.6A
fixture arms  410.28C
fixture conductors within 3 inches of ballast 90 degree  410.33
fixture stems no splices   410.28C
fixture wire ampacity taps  240.5B(2)
fixture wire application provisions  402.3
fixture wire dimensions  Chapter 9 Table 5
fixture wire insulation table  402.3
fixture wire insulation thickness  table 402.3
fixture wire name table  402.3
fixture wire outer covering table  402.3
fixture wire specifications  table 402.3
fixture wire table  402.3
fixture wire type letter table  402.3
flameproof  "d"  505.2
flameproof protection type  505.8A
flammable anesthetics  517.2
flammable anesthetizing locations  517.2
flammable gases or vapors Class I location 500.5B
flared entry  300.4F ex
flashers  404.5  600.6B
flash protection  110.16
flatiron 422.46
flax  500.5D(1)
flexible cord and cable derate table  400.5
flexible cords and cable ampacity table  400.5A
flexible cords and cable table  400.4
flexural capability  426.21B  427.17
floating buildings  90.2A
floor box  250.146C  314.27C
floor receptacle counts as wall receptacle 18in or closer  210.52A(3)
flue  450.24
fluorescent fixture in closet clearance 6 inches 410.8D4
fluoroscopic equipment  660.23A
flush deck box  680.24A(2)
flush position  312.3
footlight  520.2
footswitch  665.7B
forbidding  110.27C
forced cooled bus  368.25 ex.
foreign materials-paint, plaster, cleaners, abrasives  110.12C
foreign system  110.26F 1b
forest  230.24B  225.18(4)  830.11D(3)
forest clearance service 18 feet  230.24
forming shell  680.2
fountain  680.2
four and eleven sixteenths box dimensions table  314.16A
four quarter bends equals 360 degrees  348.26
four square box dimensions table  314.16A
four way switches  404.2
FPN fine print note  90.5C
fraction major .5 or larger  220.2B
frame  551.2
framing members  314.23 D1
free air ampacity table  310.17
free conductor 6 inches  300.14
free from shorts or grounds 110.7
free-standing bar-type counters  210.52A(2)
freezing of piping  422.50
frost  300.50B  300.5J
frost heaves  300.5J FPN
FD box standard dimensions table  314.16A
FS box standard dimensions table  314.16A
fuel cell  692.2
full shoe bender table  344.24
fungus  334.116B
fused switches  404.17
fuses in parallel  240.8
future increases, FPN  90.1B
gallery, location live parts 110.27A(3)
galvanic action  342.14
garage cable table  400.4 note 4
gasoline dispensers drawing  514.3
gas piping  250.104B
gas piping system  250.52B(2)
gas pressure  326.40
gastight  332.2
general lighting demand factors  220.11
generating plant not covered  90.2B|
generator terminals conductors  240.22
gfci 527.6B1
glass or porcelain knobs, racks, brackets  225.12
glue houses  300.6C FPN
goosenecks in service  230.54C
grain  500.5C 1
granular material  300.5F
gravel  314.29 ex
gravity  404.6
gravity not close knife switch  404.6
gray  200.9A  200.10B-C  200.10D  210.5A  310.12A
gray  322.120B FPN  400.22A-C
gray color may have been used as ungrounded in past  200.7C FPN
gray conductor grounded  200.7
grazing  230.24B  225.18(4)  830.11D(3)
grazing land clearance service 18 feet  230.24
grease, cooking  410.4C(2)
green  200.6A-E  250.28B  250.119A-C  250.126
green  310.12C  400.23A-B  517.160  520.53H2
green finish visible grounding  250.28B
green with one or more yellow stripes  250.119
grid ceiling  300.11A
grommets protect NM cable  300.4B(1)
grooves  400.22F
ground detector  250.36 (3)
grounded single phase 240.20B(2)
grounded, concrete, brick or tile walls  110.26A (1)
ground-fault current path  250.1
ground fault definition  250.2
ground fault protection maximum 1200 maximum time  230.95A
grounding drawing  250.4
grounding electrode conductor table  250.66
grounding requirements table  250.3
grounding symbol drawing  250.126
grounding type receptacle drawing  551.46C
ground movement
ground return  110.19
ground ring  250.52A 4  250.52F
Group A Locations  500.6A(1)
Group B Locations  500.6A(2)
Group C Locations  500.6A(3)
Group D Locations  500.6A(4)
Group E Locations  500.6B(1)
Group F Locations  500.6B(2)
Group G Locations  500.6B(3)
grouped  520.2
grouping of disconnects  230.72
guest room receptacle placement  210.60B
guest rooms in hotels motels receptacle placement  210.60A
guide rail fasten 620.34
guys as support for mast  230.28
gymnasiums  680.60
gypsum wall or ceiling   314.20
habitable rooms  210.8A
hair dryer hand held  422.41
hallway 10 foot or more must have at least one receptacle  210.52H
handhole  410.15B 1
hand hole for metal pole light  410.15B
hand lamps  250.114(3)E
hand lamps portable  410.42B
handy boxes (4X2 1/8X) standard dimensions table  314.16A
hangar, aircraft  500.9
hanging rod in closet  410.8A
hard conversion  90.9C  90.9D FPN 1
hard drawn copper  810.11
hard service cord type S table  400.4
harmonic currents in neutral  310.15B (4)c
hay  500.5C1
hay dried  500.8A FPN
hazard current  517.2
header  372.2  374.2
headroom  110.26E
health care facilities  517.2
heat generated  310.10 FPN (2)
heat pump  424.61
heated area maximum 33 watts/sq ft  424.98A
heated area under floor covering max 15 watts/sq ft  424.99B
heated floor FCC  324.10F
heater cord type HPD table  400.4
heating elements resistance panels not exceed 120 watts/sq ft  426.20
heating cable, adjacent runs  424.41B
heating cable resistance type  426.2
heating panel  424.91
heating panels resistance type  426.2
heating systems  426.2
heating tape resistance type  426.2
heavy-duty lampholder 660 watts admedium 750 other type  210.21A
heavy duty lampholders minimum 600VA  220.3B(5) 
heavy duty lighting track  410.103
hedge clippers  250.1(3)D 
helically wound  348.2
hemp  500.5D(1) FPN 2
henequen  500.5D(1) FPN 2
hermetically sealed  500.2  500.7J
hexagonal configuration (six sided)  240.50C 
hexagonal head (six sided)  250.126
hexagonal-headed (six sided)  406.9B(1)
hickeys  314.16B 3  410.16D
hides (animal)  300.6C FPN
HID switches high-intensity discharge  240.83D
high harmonic neutral current in nonlinear loads  210.4A
high impedance  250.24B(3)
high-impedance grounded neutral  250.21 (4)  250.36
high impedance shunts connected to supply side  230.82
high-leg marking orange  110.15
high voltage more than 600 volts  490.2
hinged base metal pole light  410.15B ex.1
hinged panels 90 degrees  110.32
hoists in tunnels over 600 volts covered 110.51A
hoists branch circuit  610.42
holiday  527.3B
holiday decorative lighting  527.3B
hook-stick  404.8A ex 3
horizontal separation  300.21 FPN
hospital  517.2
hospital transfer switch drawing  517.30
hotel guest room  210.6A
hot tub 5 feet to switch  680.43C
house load for common area  220.32B
humidifiers  422.12 ex.
hung ceiling  300.21C FPN
hybrid system  690.2
hydrochloric acid  330.12
hydromassage bathtub  680.2
hydrotherapeutic tanks  680.62
hysteresis  300.20B FPN
IC insulated ceiling fixture  410.66A(2)
ice  810.16B
ice loading  810.16B
icing  430.91
identification with permanent plaque  225.36
IEC International Electrotechnical Commission Standard  90.1D
illumination  110.26D
immersion  422.11F(3)
immersion "o"  505.2
impact resistant pool light fixture  680.33A(3)
impedance  110.10
impedance for aluminum wires  Chapter 9 Table 9
impedance for uncoated copper wire  Chapter 9 Table 9
impedance grounded neutral  200.2
impedance heating system  426.2  427.2
impedance Z table Chapter 9 Table 5
increased safety  "e"  505.2
indicating type circuit breakers  240.81
indicative  230.77
inductive load  600.6B
individual meter socket enclosures  230.66
inductance heating system  427.2
industrial electric furnaces grounding  250.21
industrial premises neutral 20 percent  250.184D(1)ex.
industrial substations  90.2A
information technology branch circuits  645.5
infrared heating branch circuit  422.48  424.3
inrush current  430.52C 3 FPN 
inserts  374.10
insulated conductors dimensions  Chapter 9 Table 5
insulating bushing temperature not less than 300.4F
insulation thickness for fixture wire table  402.3
integral fluorescent ballast protection  410.73E
interactive system  690.2
international standards  90.1D
interstices voids between strand wires  tableC3A Note Appendix C
inverter  690.2
inverter input circuit  690.2
inverter output circuit  690.2
industrial machinery  670.2
industrial manufacturing system  670.2
instruction manual, NEC not intended as (really!)  90.1C
instrument transformers connected to supply side  230.82
instruments in switchboards protected 15 amps or less  408.32
insulated fitting 4 AWG and larger  300.4F
insulating end FCC  324.2
insulation equivalent to conductor  110.14B
insulation for fixture wire table  402.3
insulation type table  310.13
insurance inspectors  90.4
integrated heating system  427.2
interchangeability  240.54E
interior stairways switch each floor  210.70A 2C
interlocked  440.62C
interlocks mechanical  490.45B
intermediate-base pendant conductors 18AWG or larger  410.27B
international system of units SI  90.9A
interrupting rating  240.83C
intrinsically safe  500.2
intrinsically safe circuit  504.2
intrinsic safety  500.7E
intrinsic safety  "i"  505.2
iron box malleable  314.40B
irradiation equipment  660.23B
island counter space needs at least one receptacle  210.52C 2
isolated equipment grounding conductor  250.96B FPN
isolated ground  406.2D
isolated ground circuits  250.96B
isolated grounded receptacles  406.2D
isolated power systems  517.2
isolated receptacles  250.146D
isolating switch  225.51 ex  404.13
isolation transformer  426.31  517.2
istle  500.501 FPN2  500.5D(1)
jamming of conductors in raceways Chapter 9 table 1 FPN2
jars  480.6
jet system for spa  680.41
joists  424.41I
junior hard service cord type SJ table  400.4
jute  500.5D1 FPN2
kapok  500.5D1  FPN2
kitchen equipment commercial demand  220.20
knife switch  404.6
knobs porcelain  225.12
knotting the cord  400.10 FPN
kraft paper  326.112
kraft paper tape  326.112
labeled equipment  110.3B
lacquer  250.12
lakes crossing clearance  225.60C
lamp cord type C table  400.4
landscape lighting receptacle  406.8B(2)
last break equipment grounding  250.124
laundries  300.6C
laundry circuit load 1500VA  220.16B
lawn mowers  250.114(3)D
lay-in wire terminals  table  312.6B note 2
LCDI leak current detection and interruption  440.65
lead in clearance  820.10B
leakage  110.26F2
leak protection apparatus  110.26F1a
legally required standby systems  701.2
letter W for white  200.10B2
life safety branch  517.2
light blue  400.22C  504.80C
lighting track fastening  410.104
lightning arrestor shall be  230.209
limited care facility  517.2
limited smoke  352.120 FPN
limiting circuits minimizes short circuits  90.8B
line isolation monitor  517.2
line terminals interrupting rating  110.9
line-to-line  240.20B(2)
line-to-neutral leads  240.20B1
linoleum  390.2
liquid spillage FCC  324.40A
listed equipment  110.3B
live-front switchboards  250.174C
live parts  312.11A(3)
live parts balcony locations  110.27A(3)
live parts of fixtures  410.3
live parts working spaces T110.26A1
livestock  547.1A
load diversity  310.15B2 FPN
load ends of the service drop  250.24A1
load management devices  230.82
load side  408.19
load-side equipment  250.142B
lock and key  110.26
locked rooms  110.34C
locked rotor code letters table  430.7B
locked service  230.92
locking device knife switch  404.6B
locking doors for service  230.62B
lock nuts, bonding type  250.92B(4)
long time pickup setting  240.6B
long time rating x ray  660.2
long time x ray 5 minutes or longer  517.2
loop wiring  390.7
loose stock  300.21A  300.22A
loudspeaker  640.2
low-impedance circuit  250.4A5
low-smoke-producing-characteristics  300.22C(2)
low voltage 24 volts or less  551.2
low-water cutoff 680.51D
lubritoriums  514.2 FPN
luminaire maximum weight 50 pounds  314.27B
luminaires 277 volt  210.6C
m protection type  505.8G
machine shops, covered  90.2A(4)
machine tool wiring table  310.13
magnesium dust  500.6B1  FPN
magnetic forces  110.36
main bonding jumper wire, bus, screw  250.28A
maintenance  90.1B
major diameter of ellipse as circle Chapter 9 Table 8 Note 9
major fraction .5 or larger  220.2B
make or brake contacts  501.3B(3)
malleable iron  250.70
mandatory application  90.4
mandatory rules - shall  90.5A
manhole access  314.55A
manhole 100 pounds  314.53  314.50
manholes  300.3C2c  300.15L
manufactured building  545.3
manufactured home  550.2
manufactured phase  455.2
marina branch circuits  555.19
marine receptacle demand factors table  555.12
marine terminal drawing  515.3
marine terminal flammable liquids drawing  515.3
marker tape  310.11B (2)
marking shall encircle the conductor if grounded  200.6B
masonry box standard dimensions table  314.16A
mast as support for service  230.30
material handling magnet  240.4A
maximum cord and plug connected load to receptacle  210.21B(2)
maximum demand for 1-year optional calculation  220.35
maximum operating temperature for fixture wire table  402.3
MCI minimum igniting current ratio  500.6A(3)
means of attachment  225.17
meat packing plant  300.6C FPN
mechanical interlocks  490.45B
mechanical strength  110.3A(2)
medium-base pendant conductors 14AWG or larger  410.27B
medium base 300  410.53
medium drawn copper  810.11 ex.
MESG maximum experimental safe gap  500.6A(2)
messenger supported wiring feeders  225.10
metal air ducts  250.104B FPN
metal boxes standard dimensions table  314.16A
metal boxes table  314.16A
metal canopies specifications  410.38B
metal ducting  250.2 FPN
metal elbow  250.80  250.86 ex.3
metal enclosed switchgear  230.211
metal frame of a building  250.52A(2)
metal lath  424.41C
metallic plugs with nonmetallic enclosures  110.12A
metal oxide arrester  280.4B FPN2
metal sheaves  250.136B
metal shield connections FCC  324.2
metal supported wire  396.2
metal tape armor  330.116
metal water pipe  250.52A(1)
metal wireways  376.2
metric designator  300.1C  314.28A1
metric designator equivalents table  4  Chapter 9
12    3/8
16    1/2
21    3/4
27    1
35    1 1/4
41    1 1/2
53    2
63    2 1/2
78    3
91    3 1/2
103    4
129    5
155    6
metric designator table  300.1C
mezzanine floors  110.33B
middle phase B  408.3E
milk  500.5C(1) FPN
minimum size conductors  230.23
minimum size conductors table  310.5minimum size feeders  215.2A(2)
mining operations clearance  225.60C
mixer  640.2
mobile home  550.2
mobile home example calculation Appendix D11
mobile home lot  550.2
mobile home optional calculation table  550.18C
mobile home park  550.2
mobile shovels covered  110.51A
mobile stanchions  513.7F
mobile x ray  517.2  660.2
module  690.2
mogul-base  410.27B
mogul base 1500  410.53
mogul base pendant conductors 14AWG or larger  410.27B
molded case circuit breakers  240.85 FPN
momentary rating x ray  660.2
momentary rating x ray not exceed 5 seconds  517.2
monitoring system  240.12
monorail  610.14G  610.15F
motel guest room  210.6A
motor aspects diagram  430.1
motor circuit aspects example calculation Appendix D8
motor circuit taps  240.20F
motor control center illumination  110.26D
motorcycles  625.2
motor frames grounding  430.142
motor full load current AC 1 phase table  430.148
motor full load current DC table  430.147
motor full load current three phase table  430.150
motor home  551.2
motor maximum protective devices table  430.52
motor nameplate values  430.6A(2)
moving walks  620.5A
moving walks branch circuit  620.61
multi circuit track equally divided  220.12B
multi conductor flat #4 AWG or larger  200.6E
multi element antenna systems  810.1
multi family dwelling example calculation Appendix D4(a)(b)
multi family dwelling optional calculations  220.32
multi family dwelling 208Y/120 three phase example calculation Appendix D5(a)
multi family dwelling optional 208Y/120 three phase example calculation Appendix D5(b)
multi grounded neutral 33 1/3 percent  250.184D(1)(3)(5)
multi grounded neutral primary systems  280.24B(2)
multi motor  610.43C
multi-outlet assemblies  220.3B8
multiple electrodes not less than 6' apart  250.56
multispeed motors  430.7B(1)
multi wire branch circuits  240.20B(1)
n protection type also nA. nC, nR  505.8A
nails for heating panels  424.93B(3)
name for fixture wire table  402.3
nameplate values  430.6A(2)
NEC not a design specification  90.1C
neon tubing  600.1 FPN  600.2
network powered  830.58E  830.30
neutral  310.15B(4)
neutral as current carrying  310.15B(4)c
neutral conductor 70%  All cases
neutral conductor carries unbalanced load  310.15B (4)a
new restaurant optional calculations  220.36
nickel coated copper  332.104
nipple 24 inches or less 60% no derate Chapter 9 Note 4
NIST National Institute of Standards and Technology
NM  334.10A  334.116A
NMC  334.10B  334.116B
NMS  334.16C  334.116C
nominal battery voltage  480.2
nominal voltage  110.4
non absorbent  410.39
non bridge structures  225.19B
non building structure clearance 3 feet  225.19B
non coincident loads use larger  220.21
non continuous load overcurrent device  210.20A
non ferrous  250.52A5b
non ferrous metal  404.9C
non ferrous wiring methods  300.3B(3)
non grounding type receptacles replacement  406.3D(3)
non heating leads  424.43A  424.97  426.23A  427.18A
non heating leads deicing and snow melting  210.19A(4)
non incendive circuit  500.2  500.7F
non incendive component  500.2  500.7H
non incendive equipment  500.2  500.7E
non incendive field wiring  500.2
non incendive field wiring apparatus  500.2
non inductive loads  404.14D(1)
non interchangeable type receptacles  406.3F  406.7
non interchangeability  406.7
non linear loads  450.3FPN2
non linear loads may have high harmonic neutral  210.4A
non metallic enclosures require no air gap  312.2A ex.
non metallic extension  382.2
non metallic wireways  378.2
non orderly shutdown  215.10 ex1
non power limited fire alarm circuit NPLFA  760.2
non tamperable type S fuses  240.54D
notches in wood  300.4A(2)
NPT national pipe thread  500.8D
nurses station  517.2
nursing home  517.2
nut  250.126  551.56  552.57 
o protection type  505.8A
oakum  500.5D1 FPN2
objectionable current  250.6
observation stand clearance table  680.8
occupant access  225.35  240.24
off premises source  250.164A
offset  312.6B(2) FPN
oil, cooking  410.4C2
oil-filled  410.73C
oil immersion  500.2  500.7I
oil insulated transformers  450.26
oil meal  500.5C1
oil switches  230.204A
one-circuit installation service  230.79A
one family dwelling example calculation Appendix D1(a)(b)D2(a)
one family optional example calculation Appendix D2(b)
one family optional w/heat pump example calculation Appendix D2(c)
one square foot equals .0930 square meters
on premises source  250.164B
on site generator  250.20D FPN1
on site power production facility  695.2
on site standby generator  695.2
one foot equals .3048 meters  Annex D Examples
one mile equals 5280 feet
one shot bender table  344.24
one square foot equals .093 square meters  Annex D Examples
open flame  511.3
open land clearance table  225.60
open wiring on insulators  398.2
openings to be closed  312.5A
operating handle  240.30B
operating room demand factor  220.11
operating temperature maximum table 310.13
operations of the hand six maximum  225.32B
opposite polarity in free air table  408.36
opposite polarity on same surface table  408.36
optional calculation-dwelling unit  220.30
optional calculation-existing dwellings  220.31
optional calculation-existing loads  220.35
optional calculation-multifamily dwellings  220.32
optional calculation-new restaurants  220.36
optional calculation-schools  220.34
optional calculation-two dwelling units  
optional stand by systems  230.2A  702.2
orange  215.8  230.56  408.3E  424.35  517.160A(5)
orange 480 volts  424.35
orange high leg marking 110.15
orange triangle  406.2D
orchard  230.24B  225.18(4)  830.11D(3)
orchard clearance service 18 feet  230.24
orderly shutdown  240.14  685.10
organic coating  384.100B
outer covering table  310.13
outer covering for fixture wire table  402.3
outdoor lampholders  225.24
outdoor outlets one@front one@back GFCI residential  210.52E
outline lighting  220.3B6
output circuit  692.2
outside a building under 2" concrete 230.6
overcurrent devices 42 maximum lighting/appliance  408.15
overcurrent protection  90.1D FPN
overhead conductor table  680.8
overhead spans clearance  225.19
overhead spans of conductors  225.6A
overhead spans of open conductors  225.18
overheating deteriorated by, not permitted  110.12C
overload relay table  430.32C  430.52C2
overload units table  430.37
overpressure limit control  424.74
overtemperature limit control  424.73
over voltage protection 90.1D FPN
oxide arrester metal  280.4B FPN 2
ozone  310.6A  555.13A(2)
ozone resistant  310.6
paddle fan  314.27D  314.27D
padlock  314.56B
paint  250.12  250.96A
paint foreign material  110.12C
paired units fixture sections  410.77C
panelboard 42 overcurrent devices  408.15
panelboard wire-bending space  408.35
panic bars  110.26C(2)  110.33A
paper kraft  326.112
paper lined  410.42B1
paper tape kraft  326.112
parallel conductors  1/0 and larger  310.4
parallel conductors  250.24B2
paralleled fuses  240.8
park electrical wiring systems  550.2
park trailer  552.2
park trailer example calculation Appendix D12
parking lot, covered  90.2A1
partition interconnections  605.4
pastes  500.5C1
path for fault current  250.4B(4)
patient bed locations  517.2
patient care areas  517.2
patient equipment grounding point  517.2
patient vicinity  517.2
pedestrian traffic over roof surfaces  225.19A ex.1
pedestrians  600.9B
pendant  410.27
pendant boxes  314.23H
peninsular counter space needs at least one receptacle  210.52C2
performance area  520.2
permanent mold cast aluminum box  314.40B
permissible alterations limits  250.6D
permissive rules - shall be permitted  90.5B
perpendicular  250.52A1 ex.
PF power factor equals cosine of theta Annex D Examples
phase arrangement ABC left to right top to bottom  430.97B
phase converter  455.2
phase current in autotransformer 1/3 neutral current  450.5
phase relay  240.100A1
phase relay element  240.100A1
phase voltage  110.15
phase voltaic array bipolar  690.2
photovoltaic drawing  690.1A
photovoltaic output circuit  690.2
pickup setting  240.6B
pilot lights  408.32
pins  406.6
pipe electrode 25 ohms or less  250.56
pipeline  427.2
pipeline branch circuits  427.4
pipe organ branch circuits  650.7
pipe organs  250.112B
pit  620.24C
pits for pool equipment  680.11
plain iron  250.70
plaque  225.36
plaque required  225.37 ex.1
plaster  314.21
plasterboard  314.21
plaster foreign material  110.12C
plate electrode  250.52A6  250.52H
plate electrode 25 ohms or less  250.56
platform elevated, location live  110.27A(3)
plenums  300.21B
pliable  362.2
plug ejector mechanism  406.6C
plug fuse replacement only  240.51B
plugging box  530.2
pneumatic circuit breakers  240.80
point of attachment  225.16
point of attachment 10 feet  230.26
point of entry to attic needs switch  210.70C
polarity  422.40
polarization  324.40B  382.56
polarized attachment plugs terminal identification  200.10A ex.
polymeric braces  314.23B(2)
polymeric lens pool light fixture  680.33A(3)
polyvinyl chloride  300.7B FPN
pool  680.2
pool cover electric  680.27B
porcelain  314.41
porcelain knobs support open conductors  225.12
portable appliance  550.2
portable equipment  520.2
portable hand lamps  410.42B
portable power cable type GE table  400.4
portable power distribution limit  520.2
portable x ray  517.2  660.2
potato  500.5C(1)FPN
potential coils  408.32
potential transformers  408.32
potting compound  680.23B(2)b
poultry  547.1A
poured concrete  410.73F(3)
powder filling  "q"
power limited fire alarm sources  Chapter 9 Table 12(A)(B)
powered loudspeaker  640.2
power factor Chapter 9 Table 9 Note 2
power factor 100% lighting load  220.3A FPN
power failure  404.11
power limited fire alarm circuit PLFA  760.2
power loss hazard  240.4A
power operable  230.76
power operable switch  225.38A  
power panelboard 10% or less lighting and appliance  408.14A
power poles  384.10
power supply cord 21 feet to 36 1/2 feet  550.10D
practical safeguarding  90.1A
premises wiring  200.3
pressure plates  110.26C2  110.33A
printed tag for cable  400.6A
product safety standards UL Annex A (back of the book)
professional projector 35-70mm 5.4 perforations/inch  540.2
projector professional 35-70mm 5.4 perforations/inch  540.2
prongs  406.6
proscenium  520.2
protection against 90.1D FPN
protection designation table  505.9C(2)(4)
protection of flexible cords, cables  240.5
protection of fixture wire  240.5
protection type "n"  505.2
prudence  500.5B1
psychiatric hospital  517.2
public street clearance service  230.24
pull at joints  400.10
pull at terminals  400.10
pump in tunnels over 600 volts covered 110.51A
purged and pressurized  500.2
q protection type  505.8H
quadruplexed  392.12
raceway seal  230.8
racked conductors  314.28B
racks support open conductors  225.12
radio antenna clearance 3 feet  225.19B
radiographic equipment  660.23A
radius of conduit bends table  344.24
raft clearance table  680.8
rail clearance table  225.60
raintight service head  230.54A
raised floors  645.5D
range dryer cable type SRD table  400.4
range frames existing grounded  250.142B ex.1
range load example calculation  Appendix D6
range receptacle  210.21B(4)
rate heat dissipates  310.10 FPN (3)
rate schedule allow additional services  230.2D
rayon  500.5D(1) FPN2
reactance X(sub L) for all wires  Chapter 9 Table 9
receptacle configurations  551.46C
receptacle configuration drawing  550.10C
receptacle demand non-dwelling first 10,000 50% bal 100%  220.13
receptacle outlets 180VA single  220.3B(9)
receptacle part of a luminaire  210.52
receptacle ratings for various size circuits  210.21B(3)
recirculation system for spa  680.41
reclose automatically  430.125C(2)
recognized time  240.92
recreational vehicle  551.2
recreational vehicle park  551.2
recreational vehicle site  551.2
recreational vehicle site demand factor table  551.73
recreational vehicle stand  551.2
red  322.120C  424.35  517.160B(1)
red non heating lead 240 volt  424.35
reference grounding point  517.2
reference standards  500.4B
refractory  332.2
refrigerator  250.114
reinforcing steel  250.2 FPN 250.52A(3)
relative analgesia  517.2
remote control for service  230.70A(3)
remote control service disconnect  230.205C
removable sides of a box  314.71C
removable truck panels  230.204A ex.
removable wire terminals table  312.6B note 2
removal of a receptacle  250.148
replacement only plug fuses  240.51B
resistance elements  424.22B
resistance of electrode 25 ohms  250.56
resistance table Chapter 9 Table 5
resistive heating element  426.2  427.2
restricted access definition  240.6C
returning conductor 3-way or 4-way not white or grey  200.7C(2)
reverse the designated polarity  200.11
rheostats  430.82C
Rho  310.60A
Rho thermal resistivity values  Annex B (back of the book)
Rho concrete 55  resistivity value  Annex B 
Rho damp soil 60 resistivity value  Annex B
Rho paper 550 resistivity value  Annex B
Rho polyethylene 450 resistivity value  Annex B
Rho polyvinyl chloride 650 resistivity value  Annex B
Rho rubber 500 resistivity value  Annex B
Rho soil 90 resistivity value  Annex B
Rho very dry soil 120 resistivity value  Annex B
ridge located on exterior of grounded conductor  200.6A4
ridges  400.22F
rigid metal conduit supports table  344.30B(2)
rigid nonmetallic conduit supports table  352.30B
rising warm air to dissipate  110.13B
rivers crossing clearance  225.60C
rivets to fasten enclosure  314.23D (1)
road clearance service 18 feet  230.24
road show  520.50
roadway clearance  225.60
roadway clearance table  225.60
rocks  300.5F
rock surface  300.50A ex.6
rod electrode 25 ohms or less  250.56
rolling stock, not covered  90.2B3
roof clearance slope 4-12 3 feet 230.24A ex.2
rooftop receptacle GFCI  210.8B(2)
root mean square difference is voltage  100
rostrums  513.7E
rotary phase converter  455.2
rubber jars  480.6C
running threads  342.42B  344.42B
runways, airport  300.50A ex. 5
safeguarding   90.1A
salt  300.6C FPN
sanitizer generator no GFCI  680.44A  680.62A(1)
scatter box  530.2
school optional calculation  220.34
screw main bonding jumper  250.28A
screw ring  410.38C
screw shell fuse  240.50E
screw shell grounded conductor  200.10C
screw shell support less than 6 pounds  410.15A
screw-shell with leads white or gray  200.10D
screws to fasten enclosure  314.23D(1)
scuttle hole  320.23A
sealants for raceways identified  230.8
sealed cells  480.2  480.10B
sealing doors for service  230.62B
seals in conduit  505.16FPN
search ingenuity 500.5A FPN
seashore  300.6C FPN
secondary circuit  600.7A
secondary conductor motor table  430.23C
secondary tie  250.24A(3)
second fault  250.4B4 FPN
seed  500.5C1
selected receptacles  517.2
self-propelled mobile surface mining machinery  90.2B2
separately derived  250.21  250.30
separately derived systems  250.20D
separate spaces 210.52C(4)
separator colored  400.22D
series rating  240.86
series rating breaker  240.86B
service conductor minimum size residential table  310.15B(6)
service diagram  230.2
service head 230.54C
service lateral conductors  230.30
service mast as support  230.28
service neutral  220.22
services for dwellings minimum table  310.15B(6)
service supports clearance table  230.51C
setscrews  314.23H(2)
sharply angular substances 300.5F
sheath  330.116
sheaves metal  250.136B
shoe bender 344.24
shooting location  530.2
short circuit current rating  110.10
short circuited current transformers 110.23
short circuits minimized by limiting circuits  90.8B
short-radius conduit bodies   314.5
shorts and grounds 110.7
short sections of metal 250.86 ex.2  250.132
shoulder fittings  250.98
shovels mobile covered  110.51A
showcase cord connected  410.29
showcases  410.29C
shower area  410.4D
shower space  406.8C  404.4
shower stall threshold  410.4D
show window cable types  400.11
show window lighting 200VA per foot  220.12A
show window receptacles for every 12 feet 210.62
show windows  220.3B(7)
shunting  668.14
side rails  392.5D
signal equipment elevator  620.2
signal processing equipment audio  640.2
sign body  600.2
sign lighting  220.3B6
SI International System of Units  90.9A
silicone bronze  344.2
silicone trade name  table 310.13
sills in transformer vault 4 inches minimum  450.43B
simple apparatus  504.2
simple reactance ballasts  410.73E(2)
simultaneous interruption  230.72B
simultaneous opening of poles  225.38B  230.74
single conductor fill 53% Ch 9 T1  
single management  250.32D
single 90 degree bend  408.35 ex.3
single pole units  230.71B
sinks  210.52C(4)
sisal  500.5D(1)  FPN2
six disconnects maximum  225.33
six times the ampacity  230.208
skeleton tubing  600.2
skid mounted equipment  250.112K
skin effect  310.15C
skin effect heating system  426.2  427.2
slash rating  240.85
sliding door 680.22A6
S loops  300.5J FPN
small animals  502.9
small appliance branch circuit 1500VA  220.16A
smoke ventilator control  520.49
smoothing iron  422.43  422.45
snap-fit  384.60
snow  100 430-91
snow blowers  250.114(3)D
snow-melting branch circuit  426.3  426.4
snow melting receptacle not GFCI  210.8A(3)
soffit  600.21E
soft conversion  90.9C
soft drawn copper  810.11 ex.
soil  314.29 ex.
solar cell  690.2
solar photovoltaic system drawing  690.1A  690.1B
solar voltaic systems  690.2
soldered splices  110.14B
solder  250.148  410.71
solder prohibited in construction of a fixture box  410.71
solidly grounded neutral  250.184
solidly grounded wye systems  215.10
sound equipment branch circuits  640.8
SPA 5' to switch  680.43C
space heating branch circuits  424.3
Spanish moss  500.5D(1) FPN2
spark gap  280.24B
sparks  502.9B
speakers underwater  680.27A(1)
special permission  90.2C
specific conductor applications table  240.4G
spices  500.5C(1)
spillage  110.26F2
spliced conductors  230.46
splices soldered  110.14B
spray area  516.2
spray area drawing  516.3B(1)  516.3B(2)
spray booth  516.2
spray booth drawing  516.3B(4)
spray room  516.2
spray washer 422.49
spreaders for cable  424.44C
sprinkler system controller receptacle  406.8B(2)
square feet of 600 is one 15 amp general purpose circuit  210.11A
square feet of 800 is one 20 amp general purpose circuit  210.11A      
stables  300.6C FPN
stage equipment  410.2  520.61
stage property  530.2
stage set  530.2
stage set lighting demand table  530.19A
stainless steel  344.2  
stairway chair lift  620.5A
stairway lift branch circuit  620.61
stanchions  513.7E  513.7F
stand alone system  690.2
standard ampere ratings  240.6A
standard circuit breaker ratings  240.6
stand by generator on site  695.2
standby power systems supply side  230.82
standpipes  406.8D
staples for heating panels  424.93B(3)
starch  500.5C(1)
start-up  455.21
static phase converter  455.2
stationary appliance  550.2
steam boilers  422.11F(3)
steel clips 1/16 inch thick  300.4B(2)
steel framing members  250.2
steel plate 1/16 inch thick  300.4A(2)
steel tie wires  250.52A(3)
steel wire armor  300.19A ex.
stiffen -10 degrees C  310.13FPN  402.3 FPN
storage battery  480.2
storage cellars  300.6C FPN
storage, do not use working space for  110.26B
store lighting continuous load  100
straight pull eight times largest trade diameter  314.28A(1)
strain insulators support  225.12
strain-relief  314.23H(1)
stranded conductors 8 and larger  310.3
stranding of conductors  Chapter 9 Table 8
stress reduction  300.40
stripes  400.22F
strip heaters resistance type  426.2
strip light  520.2
strong chlorides  330.12
strut type channel raceway  384.2
strut type channel size table  384.22
stucco mesh  250.2 FPN
studs  314.16B(3)
studs and wallboard not acceptable  110.31A
subdivided load  422.11F(1)  424.72
subdivided load conductors  324.22E
subdivided load 48 amps or more  424.22B
submersible enclosures over 600 volts tunnels  110.59
submersible pump  250.112L 680.51B
submersion 680.51D
substantially white is grounded  200.10B1
substantially white terminals grounded  200.9
substation  110.31B(1)
substation, covered  90.2A(4)
substations in tunnels over 600 volts covered 110.51A
subtractive-connected  450.5A(3) FPN
suddenly moving parts  240.41
suffix D two insulated parallel  310.11C
suffix M two or more twisted spirally  310.11C
sugar  500.5C(1)FPN
suitability of equipment  110.3A(1)
sulfer hexafluoride  230.204A
sump pump  620.85
sunlight resistant  310.8D  352.120 FPN
sunroom receptacles required  210.52A
supervised industrial installation  240.2  240.90
supervised installations  210.19B(2)
supervised location  table  430.3A3
supplemental electrode  250.53D2
supply cord ampacity  240.5B(1)
supply-side equipment  250.142A
support hardware 300.6A
supports distance between open conductors table  230.51C
surface heating element  422.11B
surface metal raceway  386.2
surface nonmetallic raceway  388.2
surface temperature classification table  500.8B
surge arresters  280.2  230.209
surge arresters connected supply side  230.82
suspended ceiling  314.23D  410.16C
suspended ceilings permitted  110.26E(1)a
SWD used as switches  240.83D
swimming pool clearances drawing  680.8
swimming pool storable  680.2
switch boxes (3X2X) standard dimensions table  314.16A
switch loops  404.2A ex.
T code maximum surface temperature table  505.9D(1)
tag marking  310.11B (3)
tank clearance  225.19B
tanneries  300.6C FPN
tap conductors definition  240.2
tape armor metal  330.116 
taper 1 in 16  3/4 inch/foot  344.28
task illumination  517.2
telecommunications  250.70 (3)
telescoping sections  250.98
television antenna clearance 3 feet  225.19B
television studio branch circuits  520.41  520.52  520.62
temporary currents  250.6C
tensile stress  501.4B 4
tension  410.28F
terminal block  322.120C
termination provisions  110.14C 1
theater stage cable table  400.4 note 4
therapeutic high frequency diathermy equipment  517.2
thermal devices  240.9
thermal effects protection  90.1D FPN
thermal protection  410.73E
thermal protector table  430.32A(2)
thermal resistivity  310.60A
thermal shock  410.4C(2)
thermocouple  336.104B
thermoplastic insulation  310.13 FPN
thermoplastic trade name table 310.13
thermoset trade name table 310.13
thickness of insulation table  310.13
thermostats  424.20B
thorium dust  500.6B 1 FPN
threadless  342.42A
threadless couplings  250.92B(3)  342.42A
three times the ampacity  230.208
three way switches  404.2
through-the-roof-raceway  225.19A ex4
through-wiring  410.11
tidal high water mark 640.10A
tie circuit  450.6A(5)
tie wires  398.30E
tightening torque FPN  110.14
tighten screw 12 lb/in.  110.14B
tile wall grounded  110.26A(1)
time-current protection characteristic  240.92D
time delay  430.42D
time switches  404.5
tinned conductors  400.22E
tinsel cord type TPT table  240.5
tinsel cord table  400.5A note.
toaster heating element  422.4
top shield FCC  324.2
total hazard current  517.2
tow  500.5D(1) FPN 2
toxicity  362.100
TP thermally protected  410.73F
tracer  400.22B
tracer in braid is grounded conductor  400.22B
track lighting  410.100
track lighting 150VA per 2 feet  220.12B
trade name table  310.13
trade sizes  90.9C 1
trailer camping  551.2
trailers in tunnels over 600 volts covered 110.51A
trailing cable  250.188F
transfer switch arrangement drawing  517.41
transfer switch automatic  701.7C
transformer rated impedance table  450.3A
transformer secondary conductors  240.4F
transition assembly  324.2
transportable x ray  517.2  660.2
trash compactor cord 3 to 4 feet  422.16B(2)
trash compactors  422.16B(2)
traveling cables  620.11B
travel trailer  551.2
trays  480.8B
trees  225.26  410.16H    
triplen harmonic currents  310.4 ex 4 FPN
triplexed  392.12
tripods  410.16D
trolley-type  368.8C
trolley wires  110.19
truck camper  551.2
T-slot receptacle  406.7
tub water  680.62B(2)
tubing fill Appendix C (back of the book)
tubular heaters resistance type  425.2
tungsten-filament  404.14A(2)
tunnel  314.56
tunnel floor  110.51C
tunnel portal  110.54A
TVSS transient voltage surge suppressors  285
two-circuit installation service  230.79B
two fer  520.2
two lock nuts  250.97ex.b
two main circuit breakers  408.16A
two sets of fuses as main  408.16A
type IC recessed  410.66A 2
type letter fixture wire table  402.3
type letter table  310.13
type S adapter non-removable  240.54C
type S fuses  non-interchangeable  240.53
types of construction Appendix E (back of the book)
ultimate insulation temperature  400.5
ultimate trip current  430.32A(2)
unclassified locations  500.2
uncoated resistance Chapter 9 Table 8
under chassis wiring  550.15H
underground escavators covered  110.51A
underground mines not covered  90.2B(2)
underground water pipe metal electrodes  250.52A(1)
underwater speakers  680.27A
unfinished basement  210.8A(5)
ungrounded primary systems  280.24B(1)
uni-grounded primary  280.24B1
uninsulated conductors Chapter 9 Table 8
uninterruptible power supply UPS  645.11
unlimited length taps  240.21B(5)
unobstructed exit  110.26C(2)a  110.33A(1)a
untrained persons, NEC not a manual for  90.1C
ups uninterruptible power supply 640.9B
upstream devices  240.92B2(3)
upstream or downstream  240.92B2(3)
U pull six times  314.28A(2)
upward slant for individual conductors  230.52
uranium dust  500.6B1
vacant space  110.31A
vacuum  422.15
vacuum cleaner cord  table 400.4
vacuum cleaner cord type SV table  400.4
vapor removal  300.22A
vapor seal  368.25 ex.
vegetation  225.26
vegetation as support for overhead spans  225.26  230.10
vegetation can not support service conductors  230.10
vehicle door does not need lighting outlet  210.702B
vehicle-mounted generators  250.34B
vehicular traffic transformers  110.31D
vehicular traffic vertical clearance  225.19A ex.1
vented cells  480.10
ventilated bus  368.27
ventilation calculation method  625.28D(2)
vertical position enclosure  240.33
vertical risers  342.30B(3)
vertical rod antenna systems  810.1
vessel  427.2
voltage drop branch circuits 3% recommended but not required  210.19A1 FPN
voltage drop on feeders 3% recommended but not required  215.2A4
voltage gradients  680.26A
voltage nominal  120/ 120/240  208Y/120  240  
voltage nominal  347  480  408Y/277 600Y/347  600
volume allowance per conductor table  314.16B
"w" suffix flexible cord exposed to water  680.56B
w white grounded conductor  200.10B
walkway clearance table  225.60
wall casings  250.112M
wall mounted luminaire  314.27A ex.
wall-mounted oven calculation  210.19A(3)
wall mounted ovens existing grounded  250.142B ex.1
wallpaper  424.93A(5)
wall space two feet wide or wider need receptacle  210.52A2
warning signs  110.27C
waste disposers  422.16B(1)
waste disposer cord 18 inches to 3 feet  422.16B(2)
waste kapok baled  500.5D(1)
water clearance table  225.60
water level  555.2 (2)
water level maximum  680.2
water pipe  250.52A(1)
water runoff  406.8A
wedge-type supports  300.19A ex.
welding splices  110.14B
well  250.112M
well galvanized  314.40A
well-way  620.34
wet bar sink GFCI receptacle 6 feet  210.8A(7)
wet location conductors  310.8C
wet location 75 degree centigrade table  310.13
wet scrubbers  250.114(3)D
wheelchair  620.5A
wheelchair lifts branch circuit  620.21
white  200.6  200.7  200.9  200.10  210.5A  
white  250.58B  310.12  400.22A-C
white continuous stripes three grounded  200.6B  200.6C
white or gray grounded conductor  200.7
white striped grounded conductor  200.6
width of working space 30 inches  110.26A(2)
winding with tape  400.10 FPN
wind loading  810.16B
window clearance overhead 3 feet  226.19D
window top clearance 3 feet  225.19D1
windshield washer fluid  511.3
wire bending offset definition 312.6B(2) FPN
wire bending space table  312.6A  312.6B
 
wire binding nuts #10 AWG or smaller  110.14A
wire main bonding jumper  250.28A
wires per terminal bending space table  312.6A B
wiring methods table  392.3A
wiring space 75% at cross section in enclosures  312.8
wood  300.6C
wood braces 1X2  314.23B(2)
wooden plugs, not permitted  110.13A
wooden staves  680.42B
wood-flour  500.5C
woodwork  382.30
woodworking  430.87A  430.112A  500.5D1 FPN1
work light  520.2
wrench-tight  250.92B(2)  314.23F
written record of test performance for GFCI  230.95C
wye connected  250.20B(2)
wye-delta starting  430.32A(1)
xenon  540.2  540.13
x ray apparatus  300.20B ex. 
x ray equipment branch circuits  517.73  660.2
x ray installations  517.2
yards, covered  90.2A(2)
yellow  424.35  517.160A(5)
yellow  120 volts  424.35
yellow stripes  250.119  250.119c  400.23  517.61  520.53  
yellow stripes  550.5B  551.55B  552.43B  552.56B  555.8B
yoke  250.146A  250.146B  404.10B
yoke of receptacle multiple branch circuit  210.7C
Z for aluminum wires  Chapter 9 Table 9
Z for uncoated copper wire  Chapter 9 Table 9
zinc  300.6A  314.40B
zinc box  314.40B
zinc galvanized  250.52A(3)
zirconium dust  500.6B(1)
zone equipment  505.9C(2)
zone equipment marking format FPN  505.9C(2)
zone for fire ladders  225.19E
zone O listing  505.9B

 


 