NEC 210.52 Reading
Quiz
ElectricianEducation.com
Identify each of the below statements with a T for True or F for False in
the left margin.
1. A residential dwelling unit need not have a clothes dryer receptacle outlet.
2. A sun room shall have receptacle outlets.
3. A pantry does not need receptacle outlets.
4. Receptacle outlets can be more than 6 feet apart.
5. Receptacles shall be a maximum of 10 feet apart in a living room.
6. Receptacle outlets may not be 16 feet apart in bedrooms.
7. A wall 12 inches wide must have a receptacle outlet.
8. The wall space behind a bedroom door does count in the receptacle
measurement.
9. A floor receptacle may be within 48 inches of a wall.
10. A receptacle outlet in a living room is required on a 12" wide wall.
11. A receptacle outlet is needed on a 12 inch wide kitchen counter top.
12. All residential garages need not have a receptacle outlet.
13. A receptacle outlet shall be installed in every residential dwelling laundry.
14. An 18 foot long entry in a residential dwelling does need a
receptacle outlet.
15. A crawl space in a residential dwelling need not have a receptacle outlet.
16. A two family dwelling must have at least four outdoor receptacle outlets.
17. A bathroom with two basins may have two receptacle outlets.
18. A free standing island in a kitchen must have at least one receptacle
outlet.
19. A peninsular counter top in a kitchen must have a receptacle outlet.
20. A kitchen countertop shall have a receptacle outlet at least every 48 inches.